安規(guī)測試儀選擇:     
 
 型號  | 接地測試  | 耐壓測試  | 絕緣測試  | 泄漏電流測試  | 功率測試P,U,I, cosΦ  | 接口  | 軟件  |  Safety tester SXS50 New  | 5-30A AC             40A option             1mΩ - 1,5Ω  | 0-5 kV AC 10mA  | 50 kΩ-200 GΩ / 500V DC              2 TΩ option 1000V DC option  | FXS501  | FXS501  | RS232 included, GPIB, PLC, Ethernet in option  | SXS Pro  |  Safety tester SXS56 New  | 5-30A AC             40A option             1mΩ - 1,5Ω  | 0-5 kVAC 10mA 0-6 kVDC 4mA  | 50 kΩ-200 GΩ / 500V DC              2 TΩ option 1000V DC option  | FXS501  | FXS501  | RS232 included, GPIB, PLC, Ethernet in option  | SXS Pro  |  Safety tester SXS500 New  | 5-30A AC             40A option             1mΩ - 1,5Ω  | 0-5 kV AC 110mA  | 50 kΩ-200 GΩ / 500V DC              2 TΩ option 1000V DC option  | FXS501  | FXS501  | RS232 included, GPIB, PLC, Ethernet in option  | SXS Pro  |  Safety tester SXS506 New  | 5-30A AC             40A option             1mΩ - 1,5Ω  | 0-5 kVAC 110mA 0-6 kVDC 40mA  | 50 kΩ-200 GΩ / 500V DC              2 TΩ option 1000V DC option  | FXS501  | FXS501  | RS232 included, GPIB, PLC, Ethernet in option  | SXS Pro  |  Safety tester 2745A  | 3-40A DC              up to 600mΩ  | 0-5 kV AC             40mA 0-6 kV DC             10mA  | 0-10 GΩ             50/100/500/             1000V DC  | -  | -  | RS232 in option  | No  |  Safety tester PST500  | 100 mA, 200 mA,             10A, 25A,              12V AC  | 0-5 kV AC 500VA  | 0-1 GΩ  | EN60335-1 EN60950             EN598-1             EN61010  | Until 16A single phase  | RS232  | No  |  Line leakage tester FXS501(slave) single or three phases  | XS Series  | XS Series  | XS Series  | IEC335, IEC950, IEC598, IEC601, IEC1010, IEC990  | Up to 63 A single phase or three phases  | RS232 included, GPIB, PLC, Ethernet in option  | SXS Pro  |  Line leakage tester FMG500 (master)  | -  | -  | -  | IEC335, iEC950, IEC598, IEC601, IEC1010, IEC990  | Up to 63 A single phase or three phases  | RS232 included, GPIB, PLC              in option  | SMG Pro  |  
 
 
 應用領(lǐng)域:  
  電子設備生產(chǎn)廠,實驗室,高速產(chǎn)線,維修等各類要求符合低電壓指令要求的部門 ·IEC 335 家用電氣的安全(洗衣機,咖啡壺,電冰箱,電暖氣,電磁爐等) ·IEC 204 工業(yè)設備的安全(壓縮機,電動工具等) ·IEC 598 照明工業(yè)的安全(街燈,燈具,醫(yī)療照明燈,燈泡) ·IEC 601 醫(yī)療企業(yè)的安全(掃描儀,手術(shù)設備,X光機,電子床) ·IEC 950 信息科技工業(yè)的安全(調(diào)制解調(diào)器,衛(wèi)星接收機,服務器,打印機) ·IEC 1010 測量,控制和實驗室的安全(電子儀表,測試測量設備等) ·IEC61215,IEC61730-2,UL1703 太陽能電池板的安全 
 
 安規(guī)測試儀注意事項 注意的是直流高壓輸出是負電壓,而地為正極。測試電容時,在電容器兩端加上電壓時有一充電過程,此時在測試電路中有一充電電流,當該電流大于所設定的漏電電流值時,耐壓測試儀就會報警,使測試中斷,無法進行。因此,安規(guī)測試儀在測試時,應緩慢增加電壓,充電電流小于所設定的漏電電流值,直到規(guī)定測試電壓,進行測試。而不能采用固定電壓,復位—啟動方式進行測試.在交流回路中相當于直流回路中的電阻,因此,安規(guī)測試儀在交流回路中就產(chǎn)生一個電流,當該電流大于所設定的漏電流值時,耐壓測試儀就會報警,使得測試中斷,無法進行。因此,在測試前,應先計算好電容器的容抗(Xc),再算出在測試電壓下的回路電流值,然后調(diào)節(jié)耐壓測試儀漏電流預置值,使其略大于回路電流值,再進行測試。J)測試電纜等分布電容大的元件(設備)要等同于電容器測試。 
 
  |